Find and Fix Heat Pump Refrigerant Leaks, Not Just Top Up

Leak located, repaired and pressure-tested before recharge. Certified for R410A, R32 and R454B.

  • Electronic and bubble leak search
  • Nitrogen pressure test after repair
  • Deep vacuum and weighed-in charge
  • R410A, R32, R454B certified
Diagnostic first, written quote second From $300
Request a Free Load Calculation + Quote Call 24/7: (647) 277-5401
Paperwork submitted5-day turnaroundNo subcontractors
Technician using an electronic leak detector at a flare fitting behind a ductless head
$780 installed Liberty Village, Toronto
-30C Rated Cold Spec
  • 17+ Years Combined
  • Red Seal + TSSA + ESA + HRAI
  • Rebates to $14,100
  • Mitsubishi + Daikin + Fujitsu Certified
  • 24/7 Emergency Repair

Heat pump refrigerant leak repair in Toronto. Low charge means a leak. A heat pump is a sealed system, so it doesn’t “use up” refrigerant. Topping up without finding the hole is money down the drain. We locate the leak, repair it, nitrogen pressure test, pull a deep micron vacuum and weigh in the charge. $300-$1,200 depending on location and refrigerant. Certified for R410A, R32 and R454B.

Signs your heat pump has a leak

  • Heating or cooling getting weaker over weeks
  • Ice or frost on the indoor refrigerant lines or a heavily iced outdoor coil
  • Longer run times and a higher hydro bill
  • Hissing at the outdoor unit or a head
  • An oily stain at a flare, joint or valve
  • Another company “topped it up” and it came back

Where do leaks happen?

LocationHow commonNotes
Flare connections (ductless heads)Most commonUnder-torqued or cracked flares
Brazed jointsCommonPoor braze, no nitrogen purge
Indoor or outdoor coilModerateCorrosion on older units
Service valves / coresLess commonEasy fix once found

How do we find it?

An electronic leak detector first, then a bubble test at every suspect fitting, then a hands-and-eyes inspection for oil trace, which shows up where refrigerant oil escapes. On hard cases, a nitrogen standing pressure test isolates sections of the system. Most leaks on multi-zone and mini-split systems turn out to be at a flare.

How is it repaired properly?

  1. Refrigerant recovered
  2. Leak repaired: re-flared, re-brazed under nitrogen, or component replaced
  3. Nitrogen pressure test, held long enough to prove it
  4. Micron vacuum to pull out air and moisture
  5. Charge weighed in to spec, then verified with superheat and subcooling

This is the same standard as a new install, and it’s done under CSA B52 practice by ODS-certified techs.

Liberty Village case

Condo-townhome mini-split losing heat every few weeks after another company topped it up twice. We traced the leak to a cracked flare at the indoor head. Re-flared, pressure-tested, recharged by weight. $780, one visit.

Repair or replace?

Leaks on corroded coils in older R410A units tend to come back, and R410A keeps getting pricier under the phase-down. If that’s your situation, we put a heat pump replacement price next to the repair. Regular maintenance catches slow leaks before they cost you a winter.

Our Toronto heat pump crews run leak repairs across downtown Toronto and Etobicoke. For other faults see heat pump repair, or book a leak search.

The Problem

What goes wrong with refrigerant leak in Toronto

1. Weak heat, rising bills A low charge makes the unit run longer for less output.
2. Icing on the lines Ice on the coil or line set is a classic sign of low refrigerant.
3. Topping up without fixing Adding gas without finding the leak is a short-term patch that repeats every season.
Ontario Rebate Stack

How much can rebates take off the invoice?

Two programs stack on eligible homes. We book the audits, fill both applications and submit them on your behalf. 40-60% of install cost is commonly offset.

Program 1

Enbridge HER+

up to $7,100

Cold-climate heat pump replacing gas heat. Pre-retrofit audit first.

Program 2

Home Renovation Savings Program

$5,000-$10,000

By efficiency tier and household income. Listed equipment only.

Combined

Stacked total

up to $14,100

Pre-retrofit audit $400-$600, refunded upon install. Post-audit after commissioning.

  1. 1. Pre-audit booked before install day. Skip it and the file is usually dead.
  2. 2. Install a NEEP / NRCan listed cold-climate model, sized by Manual J.
  3. 3. Post-audit + file. We submit HER+ and HRSP for you and track the cheque.

Rebates are "up to" amounts, depend on program terms, audits, equipment listing and household eligibility, and are never guaranteed. Full rebate breakdown.

Written Manual J

Why do we run a Manual J before any quote?

Because tonnage decides everything else. Comfort at -25C, hydro bill, compressor life, rebate eligibility. A written Manual J heat loss calc per HRAI standard comes first, then Manual S equipment selection, then the price. Free, and yours to keep.

Manual J Manual S Manual D when needed HRAI standard
  • Repair-or-replace in writing If the unit is old R410A and the repair crosses the threshold, you get both prices on paper.
  • Sizing recheck on replacement Plenty of older Toronto units were oversized. Manual J tells us before we order the new one.
  • No surprise scope Diagnostic first, written quote second, work third. Nothing starts without your sign-off.

Planning refrigerant leak? Start with the load calc.

Free written Manual J, model numbers and the rebate math on one page. Then decide.

Why Us

What sets our refrigerant leak work apart

01

Fix, not top up

We find the leak before adding refrigerant. Topping up a leak is money down the drain.

02

R410A, R32, R454B certified

ODS certified and trained on the newer refrigerants.

03

Proven with nitrogen

Every repair pressure-tested before refrigerant goes back in.

04

Honest on old units

On older R410A systems, we tell you when replacement makes more sense.

How It Works

How refrigerant leak works, step by step

Phone answered 24/7. Most repairs finish on the first visit because the common parts ride on the truck.

  1. 01

    Confirm low charge

    Pressures, superheat and subcooling measured. Low charge always means a leak somewhere.

  2. 02

    Find the leak

    Electronic detector, bubble test and oil-trace inspection at flares, brazed joints, coils and valves.

  3. 03

    Repair

    Re-flare, re-braze under nitrogen, or replace the leaking component. Quoted before work.

  4. 04

    Prove it

    Nitrogen standing pressure test, then a deep micron vacuum.

  5. 05

    Weigh in the charge

    Refrigerant charged by weight to the manufacturer spec, then verified with readings.

Project Case Study

Heat Pump Refrigerant Leak Repair in Liberty Village, near Liberty Village Park

Frosted suction line at a mini-split head before the leak repair Before
Same mini-split head running normally after the leak repair After

Liberty Village, near Liberty Village Park

Condo-townhome mini-split losing heat every few weeks after another company topped it up twice. Leak traced to a cracked flare at the indoor head. Re-flared, pressure-tested, recharged by weight.

Materials
New flare fittings, nitrogen test, R410A weighed charge
Home size
Single-zone mini-split
Turnaround
One visit
Installed price
$780 installed

Project brief illustrative of a typical job in this neighbourhood. Your price depends on your Manual J and site conditions.

Our Work

Click any photo to enlarge.

Liberty Village: cracked flare re-made.
Standing nitrogen test before any refrigerant.
Charge weighed in, not guessed.
Oil stains point to the leak.
Proven Results

Toronto homeowners on our refrigerant leak work

Real installs across Toronto neighbourhoods. Rebate captures and winter performance in the owners' own words.

"Called at 8am with ice all over the outdoor unit. Tech had the defrost board on the truck. Heat back before lunch."
MRMarco R., Little Italy$620 Daikin defrost board repair
"Old unit died in January. New Fujitsu was running in two days and they actually downsized it after the load calc. Bills went down."
SLSandra L., Willowdale$13,900 Fujitsu cold-climate replacement
"Converted our Rosedale home from oil to Mitsubishi Hyper-Heat in October. Two winters, zero backup heat needed. Enbridge HER+ Oil-to-HP bonus came through at $7,100 and HRSP added $4,800. Combined covered 65% of the project."
DKDaniel K., Rosedale$18,500 Mitsubishi Hyper-Heat 4-ton + oil tank removal
"Our board approved on first submission. Six residents replaced PTACs the first month and the board scheduled a bulk upgrade after that."
PMPriya M., Harbourfront$5,400 PTAC replacement, Fujitsu wall unit, 42-unit building
"Enbridge + HRSP rebates covered 55% of install cost. Dual-fuel thermostat switches to gas below -18C, we barely notice any difference in bills."
JTJennifer T., Leaside$14,200 Daikin Fit 3-ton dual-fuel hybrid

Reviews shown are from customer projects. Individual results and rebate amounts depend on program terms and household eligibility.

Direct Answers

Heat Pump Refrigerant Leak Repair Toronto FAQ

How much does refrigerant leak repair cost in Toronto?

$300-$1,200 depending on where the leak is, how hard it is to reach, and which refrigerant the system uses. Price is quoted before work starts.

Can't you just recharge it?

A heat pump is a sealed system. Low charge means a leak. Recharging without fixing it buys a few weeks and costs you the refrigerant again.

How do I know my heat pump is low on refrigerant?

Weak heating or cooling, ice on the indoor lines or outdoor coil, longer run times, hissing, or an oily stain at a fitting. A tech confirms with pressures and superheat.

Where do heat pump leaks usually happen?

Flare connections on ductless heads are the most common, then brazed joints, coil corrosion, and service valve cores.

Which refrigerants do you work with?

R410A, R32 and R454B. Our techs are ODS certified and follow CSA B52 practice.

Should I replace instead of repairing a leak?

If the unit is older R410A and the leak is in a corroded coil, or it keeps coming back, replacement often makes more sense. We price both.

GTA Coverage

Refrigerant Leak near you

Same crews, same 5-day turnaround. Refrigerant Leak is booked most often in these service areas.

24/7 phone. Same-day no-heat dispatch.

Ready to price refrigerant leak?

Free written Manual J, model numbers and an installed price for heat pump refrigerant leak repair in Toronto. We file the rebate paperwork.

  • Rebate paperwork submitted for you
  • Workmanship warranty + manufacturer parts coverage
  • Red Seal, TSSA, ESA, HRAI in-house
(647) 277-5401 Get Free Load Calc →